Home > Heating > Electric Heaters > Electric Ceiling Heaters
Markel | F3484 Commercial Recess Mounted Ceiling Heater | 4 KW | 208 Volt 1 Phase 19.2 Amps
Markel F3484 Image

Markel | F3484 Commercial Recess Mounted Ceiling Heater | 4 KW | 208 Volt 1 Phase 19.2 Amps

Item Id: Markel-F3484
review 0 Review(s)
0
Review this item Review this item
Your Price: $940.00
On sale:
$752.00
Usually Ships In: 4 Weeks
Ships By: UPS or FedEx Ground. Multiple quantities may ship via truck.
Weight: 50 (Lbs.)
Links To Product Literature:
Markel 3480 Catalog
Markel 3480 Installation Guide
Free Shipping
Quantity
Email a friend Email a friend
Add to Wish List Add to Wish List
Choose Options
Voltage And Amperage Confirmation *REQUIRED
I Have Confirmed That My Electrical Service Is Compatible With The Voltage And Amp Draw Of This Heater
Markel 3480 Series Factory Installed Control Options
Transformer With 24V Secondary And 24V Relay A1 [+$70.00]
Disconnect Switch S [+$87.00]
Thermostat / Transformer / Disconnect Switch TA1S [+$204.00]
Single Pole Thermostat And Transformer With 24 Volt Secondary And 24 Volt Relay TA1 [+$127.00]
Transformer With 24V Secondary And 24V Relay And Disconnect Switch A1S [+$158.00]
Double Pole Thermostat T2 [+$69.00]
Double Pole Thermostat And Disconnect Switch T2S [+$155.00]
Relay Control Voltage Same As Heater (Control Voltage Field Supplied) R [+$43.00]
Relay 24V Control Voltage (Control Voltage Field Supplied) R1 [+$70.00]
Relay 120V Control Voltage (Control Voltage Field Supplied) R2 [+$65.00]
Markel 3480 Series Field Installed Control Options
Line Voltage Double Pole Wall Thermostat ET5DS [+$22.00]
24 Volt Wall Thermostat UT1001 (Requires Transformer And Relay) [+$18.00]
Markel 3480 Series Factory Installed Louver Diffuser
Louver Diffuser L (Factory Installed) [+$50.00]
Markel 3480 Series Recess Frame
Recess Mounting Frame For Plaster Ceilings PT3480 [+$79.00]
Description

- White powder coated 20 Gauge grill.
- 208V, 240V, & 277V units have manual reset thermal limit.
- 480V units have manual reset thermal limit, 24V control transformer, and 24V relay (A1 suffix).
- Enclosed steel fin sheath element.
- Rough in dimensions: 23-1/16” sq. x 9-1/8” deep.

Product Specifications
Contractor shall supply and install heavy duty ceiling mounted forced air electric heater(s) of the wattage, voltage and phase as indicated on the plans. The heater shall be so designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by means of an electric motor and axial flow fan blade.

Heaters shall be recessed type and mounted flush with the finished ceiling. The return grille assembly shall be constructed of a one piece heavy gauge steel with 1/4” slots for return air and concentric rings for uniform air discharge. Grille assembly shall be attached to chassis by tamper-resistant (allen head) machine screws. All parts of enclosure shall be heavy Gauge steel, zinc coated both sides and finished in neutral off white powder coat paint. Enclosure shall be constructed of 1/6” x 3/8” rounded edge horizontal steel louvers which shall be spaced for maximum opening of 5/16”. Louvers shall be welded at every intersection to evenly spaced 1/8” diameter vertical members.

Motor shall be permanent lubricated, unit bearing, totally enclosed, impedance protection. Motors shall operate at no more than 1300 RPM and shall be same voltage as the heater. Heaters shall have a rating of 425 CFM at 710 F.P.M.

Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins. Each sheathed element shall consist of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by magnesium oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2” cold conductor pins extending into sheath and shall have a density of no more than 60 Watts per inch. Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded. For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted.
Heaters shall be ETL listed.

Notes
Optional controls must be factory installed. Field installation is not acceptable and violates Listing and factory warranty.

480V units include 24V transformer and relay as standard (A1)

  • only TS option control section can be added. Depth dimension of all 480V models is 10-7/8”

Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw designed for 8 to 12 foot ceilings.

Unit Weight: 50 lbs.

Recommended Remote Thermostats:
Line Voltage: Single Phase 208-240V ET5DS
Single Phase 277V ET5SS
Three Phase TW1512
Low Voltage: UT1001