Free Ground Shipping To The Continental US
Contact H-Mac

Toll Free: 877-301-4660

Call For Volume Discounts

Modine | C1408 Cabinet Unit Heater | Floor Mount | Bottom Inlet - Front Outlet | 79,500 BTU/HR (200F Hot Water, 1 Row Coil) | 115 Volts 1 Phase

Price as configured: $0.00

Usually Ships: 2-3 Weeks

Certain options and accessories may extend the lead time. Please see options and accessories for details. Ships via Truck Freight.

Shipping

Quick Overview

Modine Cabinet Unit Heaters are perfect for those hard to heat areas that require hot water or steam heating with a unit that can not be hidden. Several cabinet styles, colors and airflow arrangements are available to meet most applications.

Modine | C1408 Cabinet Unit Heater | Floor Mount | Bottom Inlet - Front Outlet | 79,500 BTU/HR (200F Hot Water, 1 Row Coil) | 115 Volts 1 Phase

Double click on above image to view full picture

Zoom Out
Zoom In
  • Free Ground Shipping to the Continental US
  • Multiple Item Discounts. Call for a custom quote!
  • See a lower price elsewhere? Call us!
 
Configure

Configure Product


Modine | C1408 Cabinet Unit Heater | Floor Mount | Bottom Inlet - Front Outlet | 79,500 BTU/HR (200F Hot Water, 1 Row Coil) | 115 Volts 1 Phase

  • - Modine53914
    +$108.00
  • 53914 Black Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with a black color, durable polyester powder-coat paint.
  • - Modine53872
  • 53872 Standard Tan Factory Finish

    +$0.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with a tan color, durable polyester powder-coat paint.
  • - Modine49723
    +$108.00
  • 49723 Beige Hammertone Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with a beige color, durable polyester powder-coat paint.
  • - Modine53878
    +$108.00
  • 53878 Sky White Hammertone Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with a sky white color, durable polyester powder-coat paint.
  • - Modine53884
    +$108.00
  • 53884 Antique White Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with an antique white color, durable polyester powder-coat paint.
  • - Modine53890
    +$108.00
  • 53890 Almond Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with an almond color, durable polyester powder-coat paint.
  • - Modine53896
    +$108.00
  • 53896 Light Gray Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with a light gray color, durable polyester powder-coat paint.
  • - Modine53902
    +$108.00
  • 53902 Dark Gray Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with a dark gray color, durable polyester powder-coat paint.
  • - Modine53908
    +$108.00
  • 53908 Medium Bronze Factory Finish

    +$108.00

    After assembly and welding operations are completed, the entire cabinet unit is treated for prevention of rust and corrosion. Entire cabinet is finished with a medium bronze color, durable polyester powder-coat paint.
  • - Modine42306
    +$175.00
  • 42306 2 Row High Capacity Hot Water Coil (Factory Installed - For Hot Water ONLY)

    +$175.00

    Change the standard 1 row coil to a 2 row high capacity hot water coil, for use with water only. See page 11 of the cabinet unit heater catalog for 2 row hot water coil performance data.
  • - Modine42307
    +$26.00
  • 42307 Change Standard Left Hand Piping Connections To Right Hand Piping Connections (Factory Installed)

    +$26.00

    Change the standard left hand piping connections to optional right hand piping connections. Left and right is determined while facing the front of the cabinet unit heater. Electrical connections are on the opposite side of the piping connections.
  • - Modine42309
    +$37.00
  • 42309 Tamper Proof Front Panel Fasteners (Factory Installed)

    +$37.00

    Front panel tamper proof fasteners. Includes special tool to operate fasteners. Can NOT be ordered with front panel key lock option 42310.
  • - Modine42310
    +$56.00
  • 42310 Key Operated Locks On Control Access Doors (Factory Installed)

    +$56.00

    Key operated locks on access doors. Two locks per unit. Model CW requires control access door option 42308. Especially valuable for units located in public place, these key locks make unit controls tamper proof.
  • - Modine42311
    +$56.00
  • 42311 Key Locks On Front Panel (Factory Installed)

    +$56.00

    Key locks on front panel. Two locks per unit. Especially valuable for units located in public place, these key locks make unit's interior tamper proof. Can NOT be ordered with tamper proof front panel fasteners option 42309 as the locks and fasteners are located in the same place.
  • - Modine42319
    +$202.00
  • 42319 Aluminum Bar Grille At Air Inlet (Factory Installed)

    +$202.00

    Replace the standard stamped inlet air louvers with an architectural aluminum bar grille that looks nicer. 12 gauge extruded aluminum.
  • - Modine42327
    +$202.00
  • 42327 Aluminum Bar Grille At Air Outlet (Factory Installed)

    +$202.00

    Replace the standard stamped outlet air louvers with an architectural aluminum bar grille that looks nicer. 12 gauge extruded aluminum.
  • - Modine42393
    +$48.00
  • 42393 25% Outside Air Duct Collar On Back (Factory Installed)

    +$48.00

    25% Outside air inlet duct collar. Collar width is 1” and is located at the rear inlet.
  • - Modine42401
    +$48.00
  • 42401 100% Outside Air Duct Collar On Back (Factory Installed)

    +$48.00

    100% Outside air inlet duct collar. Collar width is 1” and is located at the rear inlet.
  • - Modine42403
    +$50.00
  • 42403 Leveling Bolts (Factory Installed)

    +$50.00

    Leveling bolts. Allows leveling of unit on uneven floors.
  • - Modine42408
    +$210.00
  • 42408 25% Manual Outside Air Damper (Factory Installed)

    +$210.00

    25% Manual outside air inlet damper. A rear inlet, single damper to permit 0% to 25% outside air. Operated by a manual knob located in end compartment.
  • - Modine42417
    +$210.00
  • 42417 100% Manual Outside Air Damper (Factory Installed)

    +$210.00

    100% Manual outside air inlet damper. A rear inlet, single damper to permit 0% to 100% outside air. Operated by a manual knob located in end compartment.
  • - Modine42425
    +$401.00
  • 42425 0% Or 100% Motorized Outside Air Damper (Factory Installed)

    +$401.00

    0% or 100% motorized outside air inlet damper. A rear inlet, single damper with motorized actuator to permit 0% or 100% outside air. If 0% outside air, than all air goes through the return air opening of the unit. If 100% outside air, than all air goes through the outside air opening of the unit.
  • - Modine42431
    +$321.00
  • 42431 0% Or 25% Motorized Outside Air Damper (Factory Installed)

    +$321.00

    0% or 25% motorized outside air inlet damper. A rear inlet, single damper with motorized actuator to permit 0% or 25% outside air. If 0% outside air, than all air goes through the return air opening of the unit. If 25% outside air, than 25% of the total unit CFM goes through the outside air opening of the unit and 75% of the total unit CFM goes through the return air opening of the unit.
  • - Modine42439
    +$182.00
  • 42439 2 Way Adjustable Air Discharge Louvers (Factory Installed)

    +$182.00

    Two way adjustable air deflector louvers. Cannot be ordered with high capacity 2 row coils OR aluminum bar outlet grille.
  • - Modine42447
    +$28.00
  • 42447 Upgrade Standard Motor To PSC Motor (Factory Installed)

    +$28.00

    Permanent split capacitor (PSC) motor. Offers reduced electrical consumption over standard shaded-pole motor. See page 19 of catalog for motor performance data.
  • - Modine42455
    +$454.00
  • 42455 Upgrade Standard Motor To High Static Motor (Factory Installed)

    +$454.00

    High static motor. Used to overcome up to 0.4”W.C. external static pressure. See page 19 of catalog for performance data.
  • - Modine42457
    +$117.00
  • 42457 Plug In Motor Leads (Factory Installed)

    +$117.00

    Plug-in motor. Allows removal of motor(s) or fan board without unwiring unit.
  • - Modine42458
    +$57.00
  • 42458 Electrical Disconnect Switch (Factory Installed)

    +$57.00

    Disconnect switch. On-Off DPST toggle switch to disconnect electric power (hot and neutral lines) to unit. Located in electrical end compartment.
  • - Modine42459
    +$131.00
  • 42459 Return Air Thermostat (Factory Installed)

    +$131.00

    Unit mounted return air thermostat. Temperature sensing bulb is located in return air stream, control knob in control panel. Temperature set point range 55° to 90°F. Not for use with inverted air flow arrangements. Normally used with a control valve. See Figure 6.3 in catalog.
  • - Modine23125
    +$71.00
  • 23125 Honeywell T451A3005 Light Duty Wall Mounted Thermostat (Field Installed)

    +$71.00

    Honeywell T451A3005 Manual

    Honeywell T451A3005 light duty wall mounted thermostat, 115 volt, 9.8 Amps, 44-86F setpoint range.

  • - Modine23124
    +$147.00
  • 23124 Honeywell T4051A1003 Heavy Duty Wall Mounted Thermostat (Field Installed)

    +$147.00

    Honeywell T4051A1003 Manual

    Honeywell T4051A1003 heavy duty wall mounted thermostat, 115 volt, 16 Amps, 50F-80F setpoint range.

  • - Modine90348
    +$162.00
  • 90348 Johnson Controls T22BBC-1 Medium Duty Wall Mounted Thermostat (Field Installed)

    +$162.00

    Johnson Controls T22BBC-1 Product Guide

    Johnson Controls T22BBC-1 medium duty wall mounted thermostat, 115 volt, 10 Amps, 40F-90F setpoint range.

  • - Modine23127
    +$57.00
  • 23127 Clear Plastic Thermostat Guard With 2 Keys (Field Installed)

    +$57.00

    Protects the wall mounted thermostat from damage or tampering. Includes tumbler lock and 2 keys.
  • - Modine04779
    +$89.00
  • 04779 Johnson Controls A19DAC-1 Pipe Mounted Aquastat (Field Installed)

    +$89.00

    Johnson Controls A19DAC-1 Installers Guide

    Johnson Controls A19DAC-1 pipe mounted aquastat, 115 Volt, 100F-240F setpoint range. A pipe mounted aquastat is used to sense hot water moving through the supply pipe. If the aquastat senses the correct temperature, it closes its contacts and turns on the fan. This is typically used if the boiler control panel determines when a zone requires heat. On a call for heat, the boiler control panel sends water to the unit heater, the aquastat senses the hot pipe and turns on the fan. When the zone is satisfied, the boiler control panel stops sending hot water to the unit heater, the pipe cools down, the aquastat turns off the fan. An aquastat is also occassionally wired in series with a wall mounted thermostat to prevent the unit heater fan from turning on before the supply water is hot. This prevents cold air from blowing during start-up.

  • - Modine04770
    +$206.00
  • 04770 2 Way Hot Water Control Valve (Field Installed)

    +$206.00

    2 way hot water control valve, 2 position (open/close), 115 Volt, 1" NPT, 15 PSI maximum pressure.
  • - Modine04772
    +$229.00
  • 04772 3 Way Hot Water Control Valve (Field Installed)

    +$229.00

    3 way (diverting) hot water control valve, 2 position (open/close), 115 Volt, 1" NPT, 15 PSI maximum pressure.
  • - Modine04757
    +$163.00
  • 04757 Manual Motor Starter With Thermal Overload Protection (Field Installed)

    +$163.00

    Toggle switch starter with thermal overload and off position. If overload trips, starter must be reset by turning switch to off, then back to on position.
  • - Modine04778
    +$191.00
  • 04778 Modulating Non Electric Valve (Field Installed)

    +$191.00

    Installs to unit supply piping in piping end compartment. Modulates hot water or steam flow in response to return air temperature, integral set point adjustment with remote sensing bulb located in return air stream. Responds to small changes in temperature. Requires constant blower operation. Modulating control reduces energy consumption and eliminates overheating. Temperature control range 48°-83°F. Straight through style valve, brass body. Unit sizes 2 thru 6 use 3/4" NPT, sizes 8 thru 14 use 1" NPT. System pressure not to exceed 15 psi.
  • - Modine04786
    +$51.00
     
    Qty:
  • 04786 Spare Aluminum Filter (Field Installed)

    +$51.00

    1 spare washable aluminum filter. The unit ships with 1 filter installed. Filters are removable without tools. After opening the unit’s front panel, the filter easily slides out. Cleanable aluminum filters are provided as standard.
  • - Modine04794
    +$15.00
  • 04794 Wall Gasket For Model C (Field Installed)

    +$15.00

    Rubber gasket helps form a seal between the heater and the surface it's mounted against. Great for uneven walls.
  • - Modine04758
    +$57.00
  • 04758 Wall Box For 25% Outside Air Dampers (Field Installed)

    +$57.00

    A wall box can be used with units that have 25% outdoor air intake dampers. The wall box gets mounted permanently inside the exterior wall and it allows outdoor air to pass through. Interconnecting ducting/metal sleeve between the wall box and fresh air intake on the heater is NOT included.

Total: $0.00

Usually Ships: 2-3 Weeks.  Certain Options May Extend The Lead Time.


Specification

Weight (Pounds)

190.0000

Casing Style

Floor Mount

Fluid Type

Hot Water, Steam

Dimensions

28"H x 83.75"W x 12"D

Voltage Info

115 Volts 1 Phase 60 Hertz

Capacity Info

79,500 BTU/HR (200F Water, 1 Row Coil) See Catalog For 2 Row Coils And Steam Performance

Airflow

1430

Description

Modine Model C1408 Hydronic Cabinet Unit Heater Features:
• Designed for floor mounting against a wall.
• Standard 1 row steam or hot water coil. Optional 2 row high capacity hot water coil is available.
• Quiet forward curved blowers.
• Variable speed motors with built in thermal overloads and solid state speed controls.
• Cleanable aluminum filters.
• Sound dampening insulation on heavy duty 16 gauge front panels.
• Many airflow configurations available.
• 9 colors to choose from to match any decor.
• Large selection of factory and field mounted options to meet all applications.

Literature
Warranty
Q & A
Reviews

Write Your Own Review

You're reviewing: Modine | C1408 Cabinet Unit Heater | Floor Mount | Bottom Inlet - Front Outlet | 79,500 BTU/HR (200F Hot Water, 1 Row Coil) | 115 Volts 1 Phase

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Overall